ESP filters 4,000–64,000 m³/h · CE certified · ISO 9001 · Shipping to 80+ countries

info@souniny.com / WhatsApp +86 189 2910 1713

KL-D-J ESP filter, a stainless electrostatic precipitator cabinet with pull-out cell access doors

ESP Filter · KL-D-J40 … KL-D-J640 (13 models)

KL-D-J ESP Filter — Electrostatic Precipitator

Thirteen plate-type electrostatic precipitators from 4,000 to 64,000 m³/h, built for commercial kitchen exhaust: 95%+ purification, 1–2 mg/m³ at outlet, a pull-out stainless ESP cell and a dual-drive constant-voltage power supply, in a cabinet that stacks to fit the plant room you actually have.

  • 4,000–64,000 m³/h
  • ≥95% purification
  • 1–2 mg/m³ outlet
  • 12 kV ionisation
  • SeriesKL-D-J
  • ModelsKL-D-J40 … KL-D-J640 (13 models)
  • Duty4,000 – 64,000 m³/h
  • CertificationCE

Overview

What the KL-D-J is built for

The KL-D-J is the plain ESP filter in the SOUNINY range: no water, no self-cleaning arm, no cartridge stack — a flanged stainless cabinet with a plate-type electrostatic cell inside, sized to sit in the exhaust duct between the kitchen hood and the fan. Air enters through an equalising pre-filter screen, passes a 12 kV ionisation zone where oil droplets take a charge, and is collected on oppositely charged plates in the low-voltage zone before leaving through a second screen.

It exists because the ductwork is usually already there. Most commercial kitchens have a hood, a fan and a riser; what they lack is anything that stops the grease and the visible plume before it reaches the roof. Bolting a J-series cabinet into that run is the cheapest compliant answer, and because it sits upstream of the fan on the negative-pressure side, the fan stays clean and the discharge at the roof is smoke-free.

Thirteen models cover the range from a single-burner snack counter to a food court with fifteen stalls on one riser. Cabinets stack in single, double or triple configuration, so 64,000 m³/h can be reached either by one wide unit or by a tall stack in a narrow plant room.

At a glance

Series
KL-D-J
Models
KL-D-J40 … KL-D-J640 (13 models)
Airflow / duty
4,000 – 64,000 m³/h
Certification
CE (LVD + EMC)
Supply
220 V / 50 Hz

Need the full datasheet with drawings and test references? Ask and we will send it with the quotation.

Engineering

Design decisions that show up in service

What matters more on a real installation than on a specification sheet.

01

Two-zone plate cell, 7.5 mm spacing

Ionisation and collection happen in separate zones of the same pull-out cell, so the collecting field is not disturbed by the charging electrodes. Plate spacing is held at 7.5 mm with less than 0.8 mm variation across the cell — the tolerance that decides how much surface area is actually collecting.

02

12-pass stainless cell that survives washing

Every collecting plate is formed in twelve passes with four bends and deburred edges, in stainless rather than aluminium. It is washed with water and alkaline detergent every 2–3 months and goes back in straight; thin aluminium cells distort, lose spacing and quietly stop collecting.

03

Dual-drive constant-voltage supply

Constant-voltage control tracks the load on the cell and holds the optimum purification voltage as grease builds, so efficiency does not decay in the weeks before a wash. Eight protection layers cover short circuit, arcing, open circuit, overload, soft start, transformer over-temperature, adaptive step supply and constant-voltage control itself.

04

Modular cabinet, single to triple stack

One cabinet height across the range, so a site can start with 10,000 m³/h and add capacity later by stacking rather than by replacing. Flanged inlet and outlet couple straight to standard duct, and a bottom drain port takes the collected grease out in one place.

05

Digital display and IoT interface

A circular display on the front shows high voltage and current live, and prompts for contamination level and cleaning interval. An IoT port exposes the same data to a building management system, which is what makes a twenty-branch estate maintainable from head office.

06

Insulators that shed grease

High-voltage ceramic insulators isolate the electrode from the earthed case, and their oil-shedding profile keeps grease off the insulating surface. They are removable, so an inspection or a replacement does not mean dismantling the cabinet.

Specifications

KL-D-J model range

ModelAirflow (m³/h)Dimensions L×W×H (mm)Flange W×H (mm)Power (W)Pressure drop (Pa)Cabinet
KL-D-J404,000470 × 850 × 690610 × 490300107Single
KL-D-J606,000770 × 670 × 690420 × 490300113Single
KL-D-J808,000770 × 856 × 690610 × 490300133Single
KL-D-J10010,000770 × 1000 × 690760 × 490600124Single
KL-D-J12012,000770 × 1170 × 690925 × 490600131Single
KL-D-J16016,000770 × 1570 × 6901325 × 490600125Single
KL-D-J20020,000770 × 1000 × 1270760 × 10701200129Double
KL-D-J24024,000770 × 1170 × 1270925 × 10701200125Double
KL-D-J32032,000770 × 1570 × 12701325 × 10701200121Double
KL-D-J40040,0001540 × 1000 × 1270760 × 10702400153Double, wide
KL-D-J480W48,0001540 × 1170 × 1270925 × 10702400173Double, wide
KL-D-J480H48,000770 × 1570 × 18701325 × 16701800152Triple stack
KL-D-J64064,0001540 × 1570 × 12701325 × 10702400176Double, wide

All models: 220 V / 50 Hz, plate-type stainless ESP cell at 7.5 mm spacing, ≥95% purification efficiency, 1–2 mg/m³ outlet concentration, 12 kV ionisation, IP65 protection, horizontal modular installation. Dimensions are for the cabinet body; allow at least 1 m clear in front of and behind the unit for cell removal. The shipped configuration of each unit is final.

Applications

Where this series fits — and which model to take

The recommended model is the configuration we would quote for a standard layout; longer, split or stacked runs are quoted on drawing.

Street-front restaurants under complaint

Three wok burners discharging untreated fumes into a residential courtyard above. Coupled to the existing centrifugal fan in the kitchen plant space.

Recommended: KL-D-J120

Food court centralised exhaust

Fifteen stalls on one riser, total volume too high for the original ducted exhaust and out of compliance at the roof.

Recommended: KL-D-J400 + KL-D-J240

Night market and snack stalls

No fixed duct, operator worried about complaints and being moved on. Purifier with integrated fan, running on 220 V.

Recommended: KL-D-J40

Multi-branch restaurant estates

Twenty sites of a Sichuan brand with no consistent cleaning standard between kitchens, connected to IoT monitoring.

Recommended: KL-D-J80 – J160

Hotel and canteen kitchens

Heavy but intermittent cooking load on a shared riser, where the discharge point faces a neighbouring building.

Recommended: KL-D-J160 / J200

Food processing and oil-mist extraction

Frying and roasting lines where the exhaust carries oil aerosol rather than cooking smoke.

Recommended: KL-D-J320 / J400

FAQ

KL-D-J questions, answered

What is an ESP filter and how does it remove grease?

An ESP filter — an electrostatic precipitator — charges the oil droplets in the exhaust and then collects them on plates of opposite polarity. Air first passes an equalising screen that takes out the coarse mist, then a 12 kV ionisation zone where fine droplets pick up a negative charge, then a low-voltage collection zone where the charged droplets are attracted onto earthed plates. Grease runs down the plates to a sump and out through the bottom drain, and the air leaves at 1–2 mg/m³ — visually smoke-free.

Where in the duct run should the purifier go?

Upstream of the fan, on the negative-pressure side. That keeps grease out of the fan, protects the motor and stops the impeller going out of balance. Leave at least 1 m of clear space in front of and behind the cabinet so the cell can be pulled out for washing, and keep bends and diameter changes to a minimum between the hood and the unit.

How often does the ESP cell need cleaning?

Every 2–3 months on normal duty, monthly on heavy grease such as wok, Sichuan or charcoal work. Isolate the power, pull the cell out, soak it in an alkaline detergent for about 15 minutes, pressure-rinse, dry and refit. Budget 1–2 hours. The display prompts for the interval and tracks the run hours.

Which model do I need for my kitchen?

Start from the cooking load, not the room size: roughly 2,000–3,000 m³/h per wok burner, 2,000–2,500 m³/h per metre of hood length, and multiply by 1.5–2 for grill and fry duty. Then add a 20% margin and pick the next model up. Our airflow calculator does this arithmetic, including the duct and elbow allowance, and returns the model.

Does the ESP filter remove odour?

Not on its own. The electrostatic stage removes particulate — grease, smoke, oil mist — and that is what makes the discharge visible or invisible. Odour is a gas-phase problem and needs an activated carbon stage or a UV/ozone stage after the cell. If neighbours complain about smell rather than smoke, specify the odour module with the unit.

How much pressure drop does it add to the system?

107–176 Pa depending on model, measured clean. A dirty cell adds to that, which is one reason the cleaning interval matters: a loaded cell raises resistance and drops the airflow the fan can deliver. Size the fan with the dirty pressure drop in mind, not the clean one.

Can it be installed outdoors?

Yes, with the usual precautions: shelter the cabinet from direct rain, make the electrical connections waterproof and keep the drain free. Rooftop plant decks are a normal location, and the stacked configurations are designed for exactly that.

Next step

Send the layout. We will confirm the model.

Appliance list, hood length and the duct route are enough to come back with a model, an airflow figure and a drawing. OEM and ODM enquiries welcome.

Size it in 30 seconds Chat on WhatsApp

Typical reply within one working day · MOQ 1 unit