ESP filters 4,000–64,000 m³/h · CE certified · ISO 9001 · Shipping to 80+ countries

info@souniny.com / WhatsApp +86 189 2910 1713

Product range

ESP filters and the stages around them

One technology, seven configurations. The electrostatic cell is the constant; water in front of it, carbon behind it, a wash arm inside it and a canopy around it are the variables.

  • 4,000 – 64,000 m³/h ducted
  • 95% – 98% purification
  • 220 V single phase throughout
  • CE and ISO 9001 certified

Choose by problem

Start from the symptom, not the model

Most enquiries arrive as a complaint rather than a specification. This is how each complaint maps to a stage.

What you are dealing withWhat solves itSeries
Visible smoke at the roof, grease on the wallDucted plate-type electrostatic precipitatorKL-D-J
Efficiency drops between washes; nobody has time to cleanSelf-cleaning ESP with a scheduled spray cycleKL-D-Q
Charcoal, tandoor or wok: sparks, ash, radiant heatWater spray scrubber ahead of the ESP cellKL-D-SPL
The smoke is gone but neighbours still smell fryingActivated carbon odour removal box after the cellKL-D-W
Several self-cleaning purifiers, one plant deckCentral wash-water tank with recirculationKL-D-QT
No duct, no riser, no plant roomESP cell built into the canopy, recirculatingLittle Prince
Grill smoke at a market pitch or terraceWater-cycle cart with treatment on boardKL-D-SMK

Combinations are normal: a charcoal grill is typically SPL + J + W in series, and a food court with heavy grease is Q + W on a shared riser. The order of the stages matters as much as the choice of them.

Sizing

Three figures that decide which cabinet you buy

01

Airflow

2,000–3,000 m³/h per burner, 2,000–2,500 m³/h per metre of hood, ×1.25–1.5 for high-heat cooking, +20% margin. This is what selects the model.

02

Pressure

Duct length plus 6 m per 90° bend plus 3 m per 45°, at about 1 Pa/m, plus the cell's 107–176 Pa. This is what selects the fan — and a fan that cannot deliver starves the cell.

03

Interval

How often the cell will realistically be washed decides whether you need the manual KL-D-J or the self-cleaning KL-D-Q. Purchase price is the smaller half of that comparison.

Next step

Send the layout. We will confirm the model.