No duct, no riser, no penetration
Air is captured, cleaned and returned to the room from the hood itself. Nothing is cut into the building fabric, which is what makes the unit installable in a leased space.

Integrated ESP Hood · 2,400 mm canopy, 4,500 m³/h class
A stainless canopy with the electrostatic cell, the fans and the controls built into the hood body itself — for cooklines that will never have a duct, and for kitchens where the plant room is the ceiling void above the stove.
Overview
Most ESP installations put the purifier in the duct. The Little Prince puts it in the hood. The canopy, the grease screen, the electrostatic cell, the fans and the control panel are one stainless body, so the exhaust is treated where it is captured and the cleaned air returns to the kitchen instead of going up a riser.
That matters in two situations. The first is a site with no duct at all — a mall island, a basement unit, a converted retail space where the landlord will not allow a penetration. The second is a kitchen where the duct exists but the plant room does not, and the only available volume is the space directly above the cooking suite.
Because everything is in the canopy, service happens from below: the cell pulls out of the hood body, the grease screen lifts off and the fans are reachable without opening the ceiling. Power is a standard 220 V single-phase supply.
Need the full datasheet with drawings and test references? Ask and we will send it with the quotation.
Engineering
What matters more on a real installation than on a specification sheet.
Air is captured, cleaned and returned to the room from the hood itself. Nothing is cut into the building fabric, which is what makes the unit installable in a leased space.
Because the cell is in the canopy rather than at the end of a duct, the plume reaches it before it has cooled and condensed onto duct walls — and there is no duct to clean.
The cell pulls out of the hood body and the grease screen lifts off, so maintenance happens standing at the cookline rather than on a ladder in the ceiling void.
A brushed stainless canopy that reads as part of the fit-out in an open kitchen, not as a bolted-on industrial unit.
No three-phase supply and no separate plant circuit, so the unit can go into premises that were never wired for commercial extraction.
Specifications
| Parameter | Value |
|---|---|
| Configuration | Canopy + ESP cell + fans + controls in one body |
| Canopy length | 2,400 mm |
| Body dimensions L×W×H | 2,400 × 1,100 × 945 mm |
| Rated power | 2,774 W |
| Power supply | 220 V / 50 Hz |
| ESP cell material | Stainless steel |
| Pressure drop | 400 Pa |
| Installation | Ductless — recirculating |
| Certification | CE |
The Little Prince is configured around the appliance suite below it: canopy length, cell count and fan set change with the cookline. Figures above are for the 2,400 mm standard body from the factory parameter sheet; confirm the final layout on the approved drawing before ordering.
Applications
The recommended model is the configuration we would quote for a standard layout; longer, split or stacked runs are quoted on drawing.
Open cooking mid-concourse with no exhaust shaft and a landlord who will not allow coring.
Recommended: 2,400 mm body
Below-grade kitchens where no external riser exists and recirculation is the only route.
Recommended: 2,400 mm body
Cooking in front of guests where the hood has to look like joinery and the air has to come back clean.
Recommended: 2,400 mm body
Hot food added to an existing counter with no roof access and a short lease.
Recommended: 2,400 mm body
Live egg, noodle and griddle stations inside a finished dining room.
Recommended: 2,400 mm body
FAQ
Correct. The cell, fans and controls are inside the canopy and the cleaned air returns to the kitchen. There is no external duct, no wall coring and no roof penetration, so the unit can be installed where a conventional hood cannot.
Light to medium duty: griddle, teppanyaki, noodles and boiling, light frying and light wok work. For sustained high-heat wok or charcoal grilling, the ducted ESP filter with a water-spray front stage is the right specification — a recirculating hood has a finite grease load before the cell needs washing.
Back into the kitchen. A recirculating hood does not remove heat or combustion gases, so expect the room to run a few degrees warmer and make sure the space has independent ventilation for the appliances. This is a grease and smoke machine, not a ventilation system.
Every 2–3 months on normal duty, monthly on heavy grease. The cell pulls out of the hood body and is washed with alkaline detergent and a pressure rinse, the same routine as a ducted ESP.
Canopy length, cell count and fan set are configured to the cookline. Send the appliance list and the available ceiling height and we will confirm the body and the capture geometry.
Next step
Appliance list, hood length and the duct route are enough to come back with a model, an airflow figure and a drawing. OEM and ODM enquiries welcome.