ESP filters 4,000–64,000 m³/h · CE certified · ISO 9001 · Shipping to 80+ countries

info@souniny.com / WhatsApp +86 189 2910 1713

KL-D-SPL water spray purifier unit with water curtain and spray chamber

Water Spray Purifier · SPL-50 / 100 / 150 / 200 / 300

KL-D-SPL Water Spray Purifier

A water-curtain scrubber that cools the plume, knocks down coarse grease and quenches sparks before the air reaches an ESP cell — five models from 5,000 to 30,000 m³/h, built for charcoal grills, wok lines and frying that would otherwise foul a dry precipitator in weeks.

  • 5,000–30,000 m³/h
  • Water-curtain cooling
  • Spark quenching
  • CE certified
  • SeriesKL-D-SPL
  • ModelsSPL-50 / 100 / 150 / 200 / 300
  • Duty5,000 – 30,000 m³/h
  • CertificationCE

Overview

What the KL-D-SPL is built for

A dry electrostatic precipitator is the right machine for most kitchen exhaust and the wrong one for a charcoal grill. Solid fuel brings sparks, ash and radiant heat; a wok line brings a grease load that saturates a cell in days; a tandoor brings both. The SPL is the stage that goes in front: water sprayed over a perforated plate forms a continuous curtain, the plume passes through it, and what arrives downstream is cooler, wetter and substantially less greasy.

That does three things at once. It drops the temperature so the ESP and the duct are not running against a heat load. It removes the coarse grease and the ash that would otherwise be the first thing to coat a cell. And it quenches sparks, which is the fire-risk argument that gets a solid-fuel installation past a fire officer.

Five models cover 5,000 to 30,000 m³/h. The SPL-50 and SPL-100 are compact enough for outdoor BBQ stalls and food-cart clusters; the 200 and 300 handle continuous frying lines at 20,000–30,000 m³/h. In an ecology system the SPL is the water stage — the same unit, described by its role in the train.

At a glance

Series
KL-D-SPL
Models
SPL-50 / 100 / 150 / 200 / 300
Airflow / duty
5,000 – 30,000 m³/h
Certification
CE (LVD + EMC)
Supply
220 V / 50 Hz

Need the full datasheet with drawings and test references? Ask and we will send it with the quotation.

Engineering

Design decisions that show up in service

What matters more on a real installation than on a specification sheet.

01

A continuous water film, not a mist

Water is pumped over a perforated plate to form a film the air must pass through. A film wets particles and cools gas far more reliably than a spray of droplets that the airstream can carry past.

02

Sparks quenched before the cell

Solid-fuel cooking sends embers into the duct. Arriving at an electrostatic cell, they arc and start fires. Passing them through water first is the cheapest fire precaution in the train.

03

Protects the ESP behind it

Coarse grease is the load that shortens a cell's cleaning interval. Taking it out upstream extends cell life, extends the wash interval and holds efficiency between services.

04

Temperature drop before the fan

Cooling the plume reduces the volume the fan has to move and keeps the duct and the electrical stage inside their working temperature.

05

Compact enough for outdoor stalls

The SPL-50 starts at 772 × 764 × 905 mm, which fits a night-market pitch where a full ecology train would not.

Specifications

KL-D-SPL model range

ModelMax airflow (m³/h)Dimensions L×W×H (mm)FunctionCertification
KL-D-SPL-505,000772 × 764 × 905Water-curtain cooling, dust and fire preventionCE
KL-D-SPL-10010,000on requestWater-curtain cooling, dust and fire preventionCE
KL-D-SPL-15015,000on requestWater-curtain cooling, dust and fire preventionCE
KL-D-SPL-20020,000on requestWater-curtain cooling, dust and fire preventionCE
KL-D-SPL-30030,000up to 1500 × 1625 × 1800Water-curtain cooling, dust and fire preventionCE

The SPL is a pre-treatment stage, not a final filter: it is always followed by an ESP cell, a UV stage or a carbon stage that does the fine particulate and odour work. Dimensions for models above SPL-50 are set by airflow and layout and are confirmed on the approved drawing. Water supply and drain are required on site.

Applications

Where this series fits — and which model to take

The recommended model is the configuration we would quote for a standard layout; longer, split or stacked runs are quoted on drawing.

Charcoal and solid-fuel BBQ

Dense visible smoke, embers and radiant heat — the case the SPL was designed for.

Recommended: KL-D-SPL-50 / 100

High-heat wok kitchens

Oil-mist load that would foul a dry cell within days, cooled and knocked down before the ESP.

Recommended: KL-D-SPL-100 / 150

Industrial frying lines

Continuous snack production at 20,000–30,000 m³/h of oil-laden exhaust with stable efficiency.

Recommended: KL-D-SPL-200 / 300

Tandoor and wood-fired ovens

Open flame, large particulate and strong odour in one airstream — a combination dry-only systems handle badly.

Recommended: KL-D-SPL-100

Night-market clusters

Several stalls discharging into one shared treatment point where visible smoke is the complaint.

Recommended: KL-D-SPL-50

Ecology system front stage

The water stage of a full train: spray, ESP, UV and carbon in sequence.

Recommended: KL-D-SPL-150 / 200

FAQ

KL-D-SPL questions, answered

Is a water spray purifier enough on its own?

No. Water scrubbing removes coarse grease, cools the gas and quenches sparks, but it does not capture sub-micron smoke or odour. It always sits in front of an ESP cell, a UV stage or a carbon bed — which is exactly how the ecology system arranges it.

Why put water in front of an electrostatic precipitator?

Because the two failure modes of a dry ESP are heat and grease. Water takes both out before they reach the cell: the plume arrives cooler and with the coarse fraction already gone, so the cell's cleaning interval lengthens and its efficiency holds. On solid fuel it also removes the spark load that causes fires.

How much water does it use?

The circuit recirculates from a tank, so consumption is top-up and periodic change rather than a continuous draw. Actual figures depend on airflow and run hours; we quote them with the unit because they change the operating cost.

Can it be fitted to an existing installation?

Yes, provided there is space in the duct run ahead of the ESP and a water supply and drain can be reached. It is a common retrofit where a dry ESP keeps failing on a grill or wok line.

What happens in winter?

Drain the tank if the unit will be idle below freezing. The cabinet can be supplied with trace heating for cold-climate sites — raise it at enquiry and confirm against your local minimum temperature.

Next step

Send the layout. We will confirm the model.

Appliance list, hood length and the duct route are enough to come back with a model, an airflow figure and a drawing. OEM and ODM enquiries welcome.