KL-D-W odour removal unit, a horizontal carbon filter box with front access panels

Odor Removal Unit · KL-D-W50 / W100 / W200

KL-D-W Odour Removal Unit

A horizontal activated-carbon box that sits at the end of the exhaust train and takes the odour out of air the ESP has already cleaned — 90% odour removal, three sizes from 5,000 to 20,000 m³/h, with a front-access filter stack that is replaced without dismantling the duct.

  • 90% odour removal
  • 5,000–20,000 m³/h
  • Activated carbon
  • Front-access filters
  • SeriesKL-D-W
  • ModelsKL-D-W50 / W100 / W200
  • Duty5,000 – 20,000 m³/h
  • CertificationCE

Overview

What the KL-D-W is built for

An ESP filter solves the visible half of a kitchen exhaust problem. The plume goes, the grease stops running down the wall, and then someone two floors up says the restaurant still smells of frying. That is the gap the KL-D-W fills: it is a carbon box, placed after the electrostatic stage, whose only job is to take odour compounds out of air that is already clean of particulate.

Order matters. Carbon is a gas-phase adsorber, and grease blinds it in days. Put the W series after the ESP — never instead of it — and the carbon sees air at 1–2 mg/m³ with the grease already collected, which is the only condition under which a carbon bed lasts long enough to be economic.

The body is horizontal, flanged on both ends, and sized to the duct rather than to the plant room: 800 mm deep across all three models, with the height and length stepping up with airflow. The filter stack comes out of the front through two hinged doors, so a carbon change is a service visit, not a rebuild.

At a glance

Series
KL-D-W
Models
KL-D-W50 / W100 / W200
Airflow / duty
5,000 – 20,000 m³/h
Certification
CE (LVD + EMC)
Supply
220 V / 50 Hz

Need the full datasheet with drawings and test references? Ask and we will send it with the quotation.

Engineering

Design decisions that show up in service

What matters more on a real installation than on a specification sheet.

01

Carbon sees clean air, so it lasts

Placed after the ESP cell, the bed adsorbs odour rather than grease. A carbon stage in front of the precipitator is the single most common specification mistake in kitchen exhaust — it saturates within weeks and then does nothing at all.

02

90% odour removal

Rated at 90% on the odour fraction, which is what turns a neighbour complaint into a passed inspection. Smoke control alone does not stop a smell complaint; it only makes the complaint harder to photograph.

03

Two carbon stages behind a screen

A pre-screen catches anything carried over from the ESP, then two carbon stages do the adsorption. The screen is washable; the carbon is the consumable, and it is the only part that has to be bought again.

04

Front access, two doors

The stack pulls out of the front face. No duct dismantling, no cutting the run, no lifting the cabinet — which is the difference between carbon being changed on schedule and carbon being changed when someone complains.

05

Horizontal body, 800 mm deep

A flat box that fits a ceiling void, a service corridor or a rooftop frame. Height and length step up with airflow; the depth stays constant, so a plant room can be planned around one dimension.

06

Steel body, electrostatic powder coat

Carbon steel with an electrostatic powder finish, inside and out, for the humid and greasy conditions at the end of a kitchen exhaust run. Flanges on both ends couple to standard duct.

Specifications

KL-D-W model range

ModelAirflow (m³/h)Dimensions L×W×H (mm)Outlet W×H (mm)Odour removalWeight
KL-D-W505,000800 × 640 × 750540 × 55090%40 kg
KL-D-W10010,000800 × 1235 × 7501135 × 55090%65 kg
KL-D-W20020,000800 × 1235 × 14001135 × 120090%100 kg

All models: horizontal installation, carbon steel with electrostatic powder coating, 90% odour removal, front-access filter stack (pre-screen plus two carbon stages), flanged inlet and outlet. Match the model to the airflow of the ESP ahead of it — a W unit running below its rated airflow loses efficiency, and one running above it gives the carbon no dwell time. Larger airflows use several units in parallel.

Applications

Where this series fits — and which model to take

The recommended model is the configuration we would quote for a standard layout; longer, split or stacked runs are quoted on drawing.

Barbecue and charcoal grills

The case the W series is most often specified for: smoke is handled upstream, the smell is what the neighbours notice.

Recommended: KL-D-W50 / W100

Apartments above a restaurant

A riser that terminates near habitable windows, where odour — not visible smoke — is the basis of the complaint.

Recommended: KL-D-W100

Heavy-smell cooking

Fish, hotpot, Sichuan and fermentation-heavy menus where the odour load survives a well-run ESP.

Recommended: KL-D-W100 / W200

Fried and fast-food lines

Continuous frying produces a persistent oil odour that reads as 'the whole street smells of chips'.

Recommended: KL-D-W50 / W100

Confined and indoor discharge

Service corridors, basement plant rooms and covered courts where treated air is returned close to people.

Recommended: KL-D-W50

Outdoor and rooftop installations

Terminations facing a neighbouring building, a terrace or a public footway where a smell complaint is a planning risk.

Recommended: KL-D-W100 / W200

FAQ

KL-D-W questions, answered

Do I need an odour removal unit as well as an ESP?

If the complaint is smell, yes. An electrostatic precipitator removes particulate — grease, smoke, oil mist — and leaves odour compounds untouched because they are gases, not particles. A carbon stage is what removes them. If nobody has complained about smell, the ESP alone is usually enough.

Where does it go in the exhaust train?

Last, after the ESP cell, and always after it. Carbon adsorbs gases but blinds quickly on grease, so it has to see air that is already down to 1–2 mg/m³. A carbon box placed before the precipitator will saturate within weeks and then pass odour straight through while looking perfectly normal.

How often does the carbon need replacing?

That depends on the odour load and the run hours, and it is the one figure we will not guess: a breakfast-only griddle and a twelve-hour charcoal grill have nothing in common. We quote a replacement interval with the unit from your menu and trading hours, and the front-access stack means the change itself is quick.

Does it add much pressure to the system?

A carbon bed is a resistance, and a saturated one is more of a resistance than a fresh one. Size the fan with the dirty bed in mind, and put the W unit where it can be reached for a change without dismantling the duct — both are cheaper than discovering the shortfall after commissioning.

Can one unit serve several kitchens?

Yes, at a shared termination: one odour stage on the common riser instead of one per tenant. The unit has to match the total airflow of everything discharging through it, which often means two or three W units in parallel rather than one large one.

Is a carbon filter enough on its own for a grill?

No. Carbon removes odour, not smoke or grease. A grill needs the particulate stage first — an ESP filter, with a water spray purifier ahead of it on charcoal — and the carbon box at the end. The W series is the last stage of a train, never the whole train.

Next step

Send the layout. We will confirm the model.

Appliance list, hood length and the duct route are enough to come back with a model, an airflow figure and a drawing. OEM and ODM enquiries welcome.

Size it in 30 seconds Chat on WhatsApp

Typical reply within one working day · MOQ 1 unit