ESP filters 4,000–64,000 m³/h · CE certified · ISO 9001 · Shipping to 80+ countries

info@souniny.com / WhatsApp +86 189 2910 1713

Guide · Selection

What size ESP filter does my kitchen need?

Sizing a kitchen purifier goes wrong in one specific way: someone measures the room. Airflow follows the cooking, and six numbers decide which cabinet you buy. Here they are, worked through on two real kitchens.

Short answer. Multiply your cooking stations by 2,500 m³/h (or your hood face length by 2,200 m³/h per metre), multiply by a cooking factor of 0.8 to 1.5, then add 20%. That figure is the airflow to specify. In the KL-D-J range it lands on a model at 4,000, 6,000, 8,000, 10,000, 12,000, 16,000, 20,000, 24,000, 32,000, 40,000, 48,000 or 64,000 m³/h — always round up.

A four-burner range with a griddle in a 180 m² restaurant does not need more air than a six-wok line in a 45 m² noodle bar. It needs less, because there is less heat under the hood and less oil going into the air. The floor area tells you how big the dining room is; it tells you nothing about the exhaust. This is the first thing to unlearn.

The six numbers

Everything that follows is arithmetic on six inputs. Four of them you can read off a drawing or count in the kitchen; two are decisions.

  1. Cooking stations. Burners, wok positions, fryer vats, griddle plates — one per roughly 600 mm of cooking face.
  2. Hood face length. The metres of canopy the cooking actually sits under, not the wall it is mounted on.
  3. Cooking type. Steam and holding at one end, charcoal and tandoor at the other. This sets the multiplier.
  4. Design margin. Normally 20%. It buys you a menu change and a cell between washes.
  5. Duct length. Straight run from hood to discharge.
  6. Bends. How many 90° and 45° elbows, because the fan has to push through them.

The first four decide the purifier. The last two decide the fan. They are separate decisions and confusing them is the second most common mistake — a purifier chosen on pressure, or a fan chosen on volume alone.

Restaurant kitchen with a range under an extraction hood and an ESP filter in the duct
Four burners and a griddle under a 3 m hood. Count the stations, measure the hood, ignore the floor area.

Rates to start from

These are the figures the industry works to and the ones the airflow calculator applies. Where a local code specifies a different minimum, the code wins — but codes are usually written around the same physics.

CookingRateMultiplier
Per burner or station2,000 – 3,000 m³/h—
Per metre of hood face2,000 – 2,500 m³/h—
Steam, boil, soup, holding—× 0.80
Pan-fry, everyday stir-fry, griddle—× 1.00
Wok range, deep fryer, chargrill—× 1.25
Charcoal, tandoor, open flame—× 1.50

Worked example one: four burners, medium cooking

A hotel kitchen: four burner positions and one griddle, so five stations. Cooking is pan-fry and griddle, so × 1.00. Margin 20%.

5 × 2,500 × 1.00 × 1.20 = 15,000 m³/h. The next model up from 15,000 in the KL-D-J range is the KL-D-J160 at 16,000 m³/h. Not the J120 at 12,000, which is what a calculation without the margin would have produced.

That gap — 12,000 versus 16,000 — is exactly the gap between a kitchen that passes its first inspection and one that is told to reduce output a year later. The margin is not padding; it is the difference between a cell running at 75% of its rated flow and one running at 94%.

Worked example two: six woks, high heat

A Chinese restaurant: six wok burners, cooking factor × 1.25, margin 20%.

6 × 2,500 × 1.25 × 1.20 = 22,500 m³/h. That lands on the KL-D-J240. Cabinet dimensions 770 × 1170 × 1270 mm, double-stack, 1,200 W. Pressure drop 125 Pa on a clean cell.

Note that the same six burners with a light-duty menu would have come out at 14,400 m³/h — a J160. The cooking factor moved the specification two model sizes. Anyone sizing purely on burner count is guessing at half the answer.

What about the duct?

The duct does not change which purifier you buy. It changes which fan you buy, and an undersized fan will starve a perfectly specified cell — the purifier then performs like a much smaller unit, and the diagnosis at the roof looks like a failed purifier.

The working rule: straight duct costs about 1 Pa per metre at 8 m/s, each 90° elbow is worth roughly 6 m of straight pipe, each 45° about 3 m. Add the hood entry (around 50 Pa), the cell's own drop (107–176 Pa depending on model) and the discharge (around 50 Pa). A 12 m run with three 90° bends and a J240 comes to roughly 255 Pa, which is a modest fan — but a 40 m run with six bends would come to over 400 Pa and change the fan entirely.

Three ways this still goes wrong

1. Sizing to the duct that exists

The temptation is to buy the purifier that fits the current duct rather than the one the cooking needs. Do the airflow calculation first, then size the duct to 8 m/s at that airflow. If the existing duct is too small, replacing it is usually cheaper than the inspection failure it will cause.

2. Counting the hood instead of the cooking

A 6 m hood with cooking under 3 m of it does not need 6 m of hood airflow. But a 6 m hood where the cooking moves around — a buffet line, a teppanyaki counter — does, because at some point the load will be at the far end. When in doubt, the hood figure is the safer basis.

3. Forgetting what the exhaust contains

Airflow sizing says nothing about sparks, ash or odour. A charcoal grill needs a water spray stage ahead of the cell, and a site with a neighbour complaint needs the carbon stage behind it. Those are separate decisions made after the airflow is known.

Do the sum once, properly

The calculator runs all of this — airflow, model, system pressure, duct diameter — and returns a model number in about forty seconds. It will not know that your duct has a tight square elbow rather than a radiused one, or that the kitchen runs 24 hours, so treat the result as a specification to confirm rather than a purchase order. Send it to us with a photograph of the hood and we will confirm or correct it in a working day.

Next step

Send the layout. We will confirm the model.

Appliance list, hood length and the duct route are enough to come back with a model, an airflow figure and a drawing. OEM and ODM enquiries welcome.

Size it in 30 seconds Chat on WhatsApp

Typical reply within one working day · MOQ 1 unit