ESP filters 4,000–64,000 m³/h · CE certified · ISO 9001 · Shipping to 80+ countries

info@souniny.com / WhatsApp +86 189 2910 1713

Note · Food industry

Air filtration systems for the food processing industry

A food plant does not have one air problem. It has a cooking line, a powder handling area, a wash-down zone and a discharge point, each with its own particulate and its own constraints.

Short answer. A food-processing filtration system combines grease removal close to the cooking, particulate filtration for powder and flour, moisture handling for steam, and carbon for odour. Media alone struggles on grease; electrostatic cells alone cannot handle gas-phase odour.

The four loads

Grease aerosol from fryers, ovens and grills. Fine, sticky, and the reason media filters saturate rather than load.

Particulate from flour, sugar and spice handling. Dry, often combustible, and a different hazard class entirely.

Steam and moisture from wash-down, kettles and steam ovens. Not a particle problem at all, and the reason a dry filter can run wet and corrode.

Odour and VOCs from cooking and from cleaning chemicals. Gas phase, unaffected by a cell.

Why hygiene changes the answer

Media that stays damp and warm is a bacterial substrate, and in a food plant that is a quality-assurance problem, not just a maintenance one. Electrostatic cells are stainless, washable and dry out between services, which is why they are preferred on grease in plants operating to a hygiene standard.

The exception is the polishing stage: a final media filter is acceptable downstream where the air is already dry and clean.

Where each stage belongs

  • At the hood or oven: baffle plus electrostatic cell, close to source, so the duct stays clean.
  • On powder lines: a dedicated extraction system, not the cooking extract — different hazard, different design.
  • After the cell: carbon for odour, sized on dwell time.
  • At the discharge: a stack with enough height and velocity to disperse what remains.

The specification question that sorts it out

Ask what each stage is removing, in what state, at what temperature. A system specified as “filtration” without that breakdown will be over-specified in one place and under-specified in another, usually with a media filter doing a job it cannot do.

For the grease stage, the commercial cell runs 4,000–64,000 m³/h with 95–98% mass removal; the ESP filter range also covers the odour stage that goes behind it.

Everything described here is what gets built into a kitchen ESP before it leaves the factory — the cell, the drain, the interlock, the fan curve.

Next step

Send the layout. We will confirm the model.

Appliance list, hood length and the duct route are enough to come back with a model, an airflow figure and a drawing. OEM and ODM enquiries welcome.

Size it in 30 seconds Chat on WhatsApp