ESP Filter
KL-D-J ESP Filter — Electrostatic Precipitator
Thirteen plate-type precipitators from 4,000 to 64,000 m³/h — the standard ducted ESP filter for commercial kitchen exhaust.
- 4,000–64,000 m³/h
- ≥95% purification
- 1–2 mg/m³ outlet
Electrostatic precipitators · 4,000–64,000 m³/h
Plate-type electrostatic precipitators for commercial kitchen exhaust: 95%+ removal, 1–2 mg/m³ at the outlet, and a stainless cell you wash instead of replace. Thirteen models, sized by the cooking load rather than the room.

The range
The ESP cell is the core of every one of them. What changes is where it sits and what happens either side of it — water ahead of the cell for charcoal, carbon behind it for odour, a wash arm inside it for sites that cannot keep a cleaning rota.

ESP Filter
Thirteen plate-type precipitators from 4,000 to 64,000 m³/h — the standard ducted ESP filter for commercial kitchen exhaust.

Self-Cleaning ESP
Stainless ESP that washes its own cell on a 1–15 day cycle — 98% efficiency, no dismantling, labour down 80%.

Smart Water Tank
Stainless tank, pump and controls that supply and recirculate wash water for a bank of self-cleaning ESP purifiers.

Water Spray Purifier
Water-curtain pre-treatment that cools the plume, removes coarse grease and quenches sparks ahead of an ESP cell.

Integrated ESP Hood
A stainless canopy with the ESP cell, fans and controls built in — ductless purification where the plant room is the ceiling void.

Water-Cycle BBQ Cart
A stainless grill cart with water-cycle scrubbing and an ESP stage on board — 98% DOP, under 65 dB, 1.65–2.5 m.

Odor Removal Unit
A horizontal activated-carbon box for the end of the exhaust train — 90% odour removal on air the ESP has already cleaned.
Sizing tool
Airflow comes from the cooking load, not the floor area. Pressure comes from the duct, not the fan label. The calculator does both in one pass and tells you which KL-D-J model covers the result, in m³/h and CFM.

Four stages, one pass: equalising screen, 12 kV charging zone, low-voltage collection plates, final screen. Grease runs down the plates to a drain instead of up the duct.

A KL-D-J cabinet sits in the duct run, upstream of the fan, on the negative-pressure side.
How it works
Dirty air passes an equalising screen that takes out the coarse oil mist. What remains is charged at 12 kV in the ionisation zone, then captured on earthed plates in the collection zone. Purified air leaves at 1–2 mg/m³ — low enough that the roof discharge is invisible.
The collected grease runs down the stainless plates and gathers at a bottom drain, where it is emptied in one place instead of being carried up the duct and onto the roof.
Applications
Wok ranges need volume. Charcoal needs water in front of the cell. A food court needs one treatment point, not fifteen. Each of those is a different specification of the same technology.

High grease load, tight urban riser, neighbours above. Sized per burner with a 20% margin.

Sparks and ash go into a water spray stage first, then the cell, then carbon for the smell.

One treatment point on the shared riser instead of a unit behind every tenant.

Continuous frying and roasting lines where the exhaust carries aerosol, not smoke.

Chaff, oily aerosol and strong odour at low volume — a three-stage arrangement, not a scaled-down kitchen unit.

Water spray, ESP, UV and carbon in sequence where one stage cannot meet the discharge limit.
Why these units hold their efficiency
An electrostatic precipitator is not a filter that clogs; it is a field that collects. Efficiency is decided by plate geometry, by how well the supply holds voltage as grease builds, and by whether anyone washes the cell on schedule. Those three things are what the design is spent on.
7.5 mm spacing, held within 0.8 mm, over a 195 mm adsorption width on 0.8 mm stainless plates formed in twelve passes. Tolerance is the difference between a cell that collects and one that arcs.
Constant-voltage control tracks the cell as grease accumulates, so the last week before a wash performs like the first. Eight protection layers keep it there without tripping.
Either the display prompts you, or the cabinet washes itself on a 1–15 day cycle. Both exist because the same failure — a cell nobody washed — causes most failed inspections.
Send the appliance list and the duct route and we will return a model, an airflow figure and a drawing. OEM and ODM builds are normal work here.
Guides
Read the condition, translate it into two numbers, then choose the technology.
Four capabilities that cannot be faked by a website, and how to verify each.
Ask these eight before comparing prices. Half of them will end the conversation.
Questions we get before an order
An electrostatic precipitator is an air-cleaning device that removes fine particles by giving them an electric charge and then collecting them on plates of opposite polarity. In a commercial kitchen it sits in the exhaust duct and takes grease, smoke and oil mist out of the airstream, so what leaves the roof is a clean, invisible discharge rather than a visible plume of cooking fume.
Four stages. A pre-filter screen knocks out the coarse oil mist. The remaining droplets pass a 12 kV ionisation zone where they pick up a negative charge. They then enter a low-voltage collection zone, where the charged particles are attracted onto earthed plates. A second screen catches anything left, and the collected grease runs down the plates to a sump and out through a drain.
Size on cooking load first. Allow roughly 2,000–3,000 m³/h per wok burner, or 2,000–2,500 m³/h per metre of hood, and multiply by 1.5–2 for grill and fry work. Then pick the next model up in the range. Our airflow calculator does this including the duct, elbow and pressure-drop allowance, and returns the model with the margin shown.
The KL-D-J range is rated at 95% or better on grease and smoke, with an outlet concentration of 1–2 mg/m³ — low enough that the discharge is visually smoke-free. The self-cleaning KL-D-Q reaches 98%. Efficiency holds only if the cell is washed on schedule; a loaded cell looks identical from outside and quietly collects less.
The cell itself needs ductwork to sit in. Where there is no duct — a mall island, a basement unit, a leased retail space — the answer is an integrated hood with the cell inside the canopy, which cleans the air and returns it to the room instead of discharging it.
For charcoal, solid fuel, tandoor or a heavy wok line, yes. Those loads bring sparks, ash and radiant heat that a dry cell handles badly. A water spray purifier in front cools the plume, quenches the sparks and takes out coarse grease before the ESP sees it, which lengthens the cleaning interval and removes most of the fire risk.
Next step
Appliance list, hood length and the duct route are enough to come back with a model, an airflow figure and a drawing. OEM and ODM enquiries welcome.