ESP filters 4,000–64,000 m³/h · CE certified · ISO 9001 · Shipping to 80+ countries

info@souniny.com / WhatsApp +86 189 2910 1713

Note · Food industry

Air purification systems for the food processing industry: gases, not just particles

Filtration removes particles. Purification is the word the industry uses for everything the particle stage leaves behind — and that is a much less settled piece of engineering.

Short answer. Purification covers odour, VOCs and fine cooking fume. Carbon adsorption is the workhorse; UV and scrubbers serve specific cases. All of them need the grease removed first, or they foul within weeks.

Carbon

The default, and the only technology that removes a broad spectrum of odour compounds at low concentration. Performance depends almost entirely on contact time and on what reaches the bed: grease blinds carbon faster than any other contaminant, which is why the cell comes first.

UV

Ultraviolet light at 254 nm damages microbial DNA; at 185 nm it generates ozone that oxidises odour. Both are real effects and both are easily oversold. In a greasy exhaust the lamp tube fouls, the effective dose collapses, and the unit continues to glow reassuringly. Where UV is used, the quartz sleeve needs cleaning on a schedule and the grease stage has to be doing its job.

Scrubbers

Wet scrubbing removes water-soluble species and cools the gas, which condenses some vapours into particles that a following stage can catch. Effective on specific processes — rendering, fish smoking — and expensive to run.

The order that works

  1. Baffle and mesh: coarse droplets and flame.
  2. Electrostatic cell: fine aerosol, 95–98%.
  3. Mist elimination and, where needed, cooling.
  4. Carbon: odour, on a replacement schedule based on loading.

Change the order and the carbon becomes a grease trap, the UV tube becomes opaque, and the running cost triples without an improvement in the reading.

What to measure

Odour concentration at the discharge, if there is a condition; particulate in mg/m³ otherwise; and the pressure drop across each stage so a blinded bed is visible before it fails a test.

The particle half of that train is the part we build: a cell from 4,000 to 64,000 m³/h, and the W series carbon stack at 5,000–20,000 m³/h behind it. The ESP purifier pages set out where each fits.

The electrostatic precipitator we would put on a job like this is the KL-D-J, in whichever size the airflow calculation returns.

Next step

Send the layout. We will confirm the model.

Appliance list, hood length and the duct route are enough to come back with a model, an airflow figure and a drawing. OEM and ODM enquiries welcome.

Size it in 30 seconds Chat on WhatsApp

Typical reply within one working day · MOQ 1 unit