Air purification for food service: the front and back of house

Food service covers everything from a two-table café to a stadium concourse. The air problem is always the same shape: a plume at the cooking surface and an odour that travels further than the smoke.

Short answer. Back of house needs grease filtration at the hood plus an extract path to atmosphere. Front of house needs ventilation and, where the kitchen is open, capture at the pass. A room purifier treats the symptom after the aerosol has spread.

Back of house

The hood captures, the duct transports, the cabinet filters, the fan drives. The only stage that changes the visible result is the cabinet: 95–98% on grease aerosol, which is what stops the plume at the roof and the grease in the duct.

Sizing is from the cooking: 2,500 m³/h per station, 2,200 per metre of hood face, a cooking factor, 20% margin.

Open kitchens

Where the cooking is on display, capture has to be better than a standard canopy — closer, with side skirts, and often with a supplementary extraction at the pass. No downstream filter compensates for a plume that has already escaped into the room.

Front of house

Dining air is a ventilation problem before it is a filtration one. CO2 above about 1,000 ppm during service means the outside-air rate is short, and that is fixed with make-up air, not with a purifier. Fine particulate from an open kitchen follows the same rule: capture it, do not chase it.

Where a purifier does earn its place

Small enclosed dining rooms with no duct route to the kitchen extract, kiosks and food halls where the landlord forbids penetrations, and rooms where the cooking is light but the air still smells of it. In those cases a recirculating unit with a real carbon stage is the correct answer — and it needs maintenance, not just installation.

The rule of thumb

Capture at the source, filter the extract, disperse at the roof, ventilate the room. Four steps in that order. Food service projects that fail usually inverted the first two, buying equipment to clean air that should never have been in the room.

The capture and filter steps are documented in the ESP filter sizing charts, and the calculator will give you the model from the station count in under a minute.

None of it is exotic: it is the standard build of an ESP filter, and the specification sheet on the front page lists every model and pressure drop.