Note · Food industry

Best IAQ systems for food production facilities: how to judge one

Every supplier claims to be the best. The useful question is narrower and answerable: best at what, under which constraint, over which period.

Short answer. Judge on removal performance at your load, hygiene compatibility, maintenance burden, energy and pressure drop, and documentation. The two most often forgotten are maintenance burden and documentation.

One: performance at your load

Not the headline percentage. Ask for outlet concentration at the inlet loading your process produces, and for the test method. A number without a method is a claim.

Two: hygiene compatibility

Can it be cleaned to a standard your quality team will accept? Are there damp media, crevices or inaccessible surfaces? Stainless cells that dry between services score better than wet media in most plants.

Three: maintenance burden

Hours per month, and who does them. A system that needs skilled labour unavailable on site is a system that will be neglected, and neglect is the largest single cause of underperformance in every installation we have surveyed.

Four: energy and pressure drop

Fan power scales with pressure drop and with the cube of airflow. A filter with 50 Pa more resistance costs money every hour of every shift; a poorly balanced system costs more than both.

Five: documentation

Specification sheet, commissioning record, maintenance log, spare parts list, and a drawing that matches what was installed. In an audited plant this is not paperwork — it is the evidence that the control is working.

The two that get forgotten

Maintenance burden and documentation, for the reason that both cost nothing at purchase and everything afterwards. A shortlist scored only on capital cost and efficiency will pick the wrong system roughly every time.

How to run the comparison

Score each candidate out of five on the five criteria, weighting maintenance burden double if the plant runs three shifts. The answer is usually obvious once it is on one page.

For the grease stage of any of those systems, the numbers needed to score criteria one and four — outlet concentration and pressure drop per model — are on the ESP filter data sheets, from 4,000 to 64,000 m³/h.

A kitchen ESP is only as good as its weakest gasket, which is why the cabinet on the front page is built around service access rather than looks.