Note · Kitchen
Carbon filtered enclosure: odour control as a box, not a bolt-on
Carbon is often bolted on afterwards: a canister in the duct, sized by whatever fits. An enclosure treats odour as part of the cabinet design, which is the difference between 90% removal and a gesture.
Short answer. A carbon filtered enclosure is a cabinet containing both a grease stage and a carbon bed, with the airflow arranged so the carbon sees air that has already been stripped of aerosol. It is the standard way to meet an odour condition on a kitchen exhaust.
Why the order matters
Carbon adsorbs gases. Grease aerosol blinds it in days: the pores fill with fat and the bed stops working while still looking intact. Every well-designed enclosure therefore puts the electrostatic stage first and the carbon second, with a mist eliminator between them if the cell is washed in place.
Sizing the bed
Residence time, not airflow. A bed deep enough to hold the air for a fraction of a second removes a measurable fraction; a thin pad at duct velocity removes almost nothing while adding pressure drop. The practical figures are bed depth, face velocity and the iodine number of the media — ask for all three.
Then size on the odour load, which follows the cooking: a fryer line produces far less odour per cubic metre than a charcoal grill.
Why an enclosure rather than a canister
- No bypass. A single pressure-tight box cannot leak greasy air around the carbon the way a flanged canister in a duct can.
- Service access. The bed is reached through a door, on the ground, rather than by dropping a section of duct.
- Weather. On a roof, one cabinet with a weatherproof lid outlasts a fabricated canister with a plastic bag over it.
- Pressure budget. One resistance to allow for, not two with a duct between them.
What it costs to run
The media is the consumable, and it is consumed faster than most sites expect: on a heavy grill line, replacement can be every few months. That is the honest argument for putting the cell in front of it — the better the grease removal, the longer the carbon lasts.
The W series is this idea packaged: 5,000, 10,000 and 20,000 m³/h, front-access carbon stack, 90% odour removal. It sits behind a cell rather than replacing one, and the ESP filter pages show where it fits in the line.
Everything described here is what gets built into a kitchen ESP before it leaves the factory — the cell, the drain, the interlock, the fan curve.
Next step
Send the layout. We will confirm the model.
Appliance list, hood length and the duct route are enough to come back with a model, an airflow figure and a drawing. OEM and ODM enquiries welcome.