ESP filters 4,000–64,000 m³/h · CE certified · ISO 9001 · Shipping to 80+ countries

info@souniny.com / WhatsApp +86 189 2910 1713

Note · Kitchen

Commercial kitchen air purifier: two different products, one name

The phrase is used for two machines that share a housing and almost nothing else. Choosing the wrong one is not a small error: one cleans the air in the room, the other cleans the air leaving the building.

Short answer. A ductless recirculating unit treats kitchen air and returns it to the room; an in-duct electrostatic unit treats exhaust on its way out. The first solves a ducting constraint, the second solves an emission or planning constraint.

Both contain a filter train and a fan. The difference is where the air goes afterwards, and that single fact changes the specification completely.

Recirculating: no duct, higher standard

A ductless unit has to return air that people are standing in. That means odour removal is not optional — carbon is mandatory rather than a nice-to-have — and the airflow has to be balanced against make-up air in the room, or the kitchen goes negative and the doors whistle.

It is the right answer where a duct is impossible: listed buildings, basement kitchens, kiosks, food halls with a landlord who will not allow roof penetrations. It is the wrong answer where a duct is available and cheap, because recirculation costs more to run per cubic metre treated.

In-duct: emission control

An in-duct electrostatic stage sits between the hood and the fan. Its job is the plume at the roof and the grease in the duct. Odour is a secondary question, handled by adding carbon after the cell if the site has a smell condition.

Airflow follows the hood, typically 2,200 m³/h per metre of face, and the cabinet is sized from that.

How to tell which one a quote is for

Look at the discharge. If the drawing shows a return grille into the kitchen, it is a recirculating unit. If it shows a duct to atmosphere, it is an in-duct filter. If it shows neither, the quote is incomplete.

Both are in the range — the ductless recirculating versions and the ducted 4,000–64,000 m³/h cabinets — and the ESP purifier page separates them by application rather than by marketing category.

If you want the short version of this note, the electrostatic precipitator page summarises the range in a table you can scan in a minute.

Next step

Send the layout. We will confirm the model.

Appliance list, hood length and the duct route are enough to come back with a model, an airflow figure and a drawing. OEM and ODM enquiries welcome.

Size it in 30 seconds Chat on WhatsApp

Typical reply within one working day · MOQ 1 unit