ESP filters 4,000–64,000 m³/h · CE certified · ISO 9001 · Shipping to 80+ countries

info@souniny.com / WhatsApp +86 189 2910 1713

Note · Buying

Electrostatic precipitator catalogue: how to read one properly

Catalogues are organised for browsing and bought from by comparison. Learning which six columns matter turns a 40-page brochure into a five-minute shortlist.

Short answer. Read model, airflow, dimensions, flange size, power and pressure drop. Then ask for the two that are usually missing: plate area and wash interval at your cooking load. Those eight numbers are the whole decision.

The six columns that matter

Model. The name encodes the airflow in most ranges — KL-D-J320 is 32,000 m³/h — which makes the table navigable but also makes it easy to order the wrong size by assuming the number means something else.

Airflow. m³/h at the stated pressure drop. If the catalogue does not say at what resistance, ask.

Dimensions. Height, width, depth, in the order the drawing uses. Check the height against the void before anything else.

Flange. The duct connection size, which determines whether the transition is a standard fitting or a fabrication.

Power. The cell supply, not the fan. Fans are sized separately against the system.

Pressure drop. 107–176 Pa across a commercial range. The loaded figure is higher; assume so.

The two that are usually missing

Plate area. The physical measure of collection capacity, and the only honest way to compare two models at the same airflow.

Wash interval at load. A single figure for every kitchen is a red flag. The interval depends on what is cooking, and a catalogue that says “monthly” for a wok range is describing a different product.

How to shortlist in five minutes

  1. Calculate the airflow from the cooking, with 20% margin.
  2. Find the smallest model at or above it.
  3. Check the height against the available void; if it fails, look at the wide or stacked variants.
  4. Check the flange against the duct you intended.
  5. Confirm the wash method you can actually sustain.

What a catalogue cannot tell you

Whether the unit fits through the door, whether the drain can reach a trap, and who will clean it. Those are site questions, and they decide more projects than the specification does.

Our own model table follows the six columns above and adds dimensions in the drawing order, so the shortlist can be worked straight off the ESP filter page without a PDF.

The dimensions, weights and pressure drops quoted here come from the ESP filter data sheets, not from a brochure rounded for print.

Next step

Send the layout. We will confirm the model.

Appliance list, hood length and the duct route are enough to come back with a model, an airflow figure and a drawing. OEM and ODM enquiries welcome.

Size it in 30 seconds Chat on WhatsApp

Typical reply within one working day · MOQ 1 unit