Electrostatic precipitator controller: reading the panel
The controller is the only part of the system that reports on the cell. Learning to read two numbers on it replaces most of the guesswork in fault-finding.
Short answer. The controller converts mains power to the high voltage the cell needs, limits current, and cuts out on a fault. Watch the kV (voltage held) and mA (current drawn): falling kV with rising mA means the cell is loading or the insulators are dirty.
What it actually does
Three jobs: step 220 V up to roughly 12 kV, rectify it, and protect the cell. The protection is the interesting part — a precipitator arc is a short circuit, and the supply has to detect it, kill the arc and re-strike without welding the plates together.
The two numbers
kV is the voltage the supply is holding. mA is the current it is delivering. Together they describe the cell's electrical condition.
- High kV, low mA. Clean, dry cell. Normal.
- Falling kV, rising mA. Loading or leakage: grease on plates, moisture, or a contaminated insulator.
- kV collapsing to near zero with trips. Dead short: a bent plate, a bridged gap, or water in the cell.
- kV normal, mA near zero. Open circuit: a broken ioniser wire or a disconnected cell contact.
What the indicator lights will not tell you
A green light means the supply is on, not that the cell is collecting. Most underperforming units show green. The two numbers are the diagnostic; the light is a power indicator.
Fault behaviour worth knowing
Most controllers retry automatically after an arc, with a delay that increases over successive trips. A unit that trips three times in an hour and settles is a unit with a marginal cell. A unit that trips continuously is a unit that needs the cell out.
Do not defeat the retry by power-cycling repeatedly: each re-strike is a small stress on the plates, and the fifth attempt will not succeed where the first four failed.
What to record
The reading after each wash. That single number, tracked over months, is how you tell a cell that is loading normally from a supply that is slowly failing — and it is the first thing we ask for when a site reports a performance problem.