Note · Technology
Electrostatic scrubber: the decision, not the description
The technology description is easy to find. The decision is harder, because both options meet the same emission limit on paper and differ by a factor of two in operating cost.
Short answer. Choose a scrubber when the gas is saturated, the aerosol is sub-micron and the site can handle liquid effluent. Choose a dry precipitator with a carbon stage when the gas is hot and dry, the load is grease, and there is no effluent consent.
Four questions, in this order. The first one usually decides it, and the other three confirm or overturn.
One: is the gas saturated?
If the exhaust is at or near its dew point — steam ovens, rendering cookers, some fryers with a water bath — a dry precipitator will run wet anyway, and corrosion and arcing follow. A scrubber is designed for that condition; a dry unit merely tolerates it badly.
Two: what size is the aerosol?
Grease smoke from a grill peaks around 0.3–1 micrometre and is collected well by a two-stage cell. Condensable organics that form aerosol only after cooling are harder, and that is where the electrostatic scrubber's agglomeration step earns its place.
Three: can the site take effluent?
A scrubber produces a continuous bleed of contaminated water. Without a trade-effluent consent and a treatment route, the design is not viable no matter how well it performs. This question kills more scrubber projects than any technical one.
Four: is there roof area?
A scrubber plus mist eliminator plus recirculation tank occupies several times the footprint of a dry cabinet for the same airflow. On a city-centre roof, that alone settles it.
The usual answer for a commercial kitchen
Hot, dry, grease-loaded gas, limited roof, no effluent consent: a two-stage cabinet with a wash cycle, plus carbon if odour is the issue. That is what nearly every kitchen in the range is built for, from 4,000 to 64,000 m³/h, and the ESP purifier list shows the model, airflow and cabinet size together so the roof fit can be checked early.
If the site has a constraint we have not covered here, the ESP purifier range includes recirculating, ducted and stacked versions of the same cabinet.
Next step
Send the layout. We will confirm the model.
Appliance list, hood length and the duct route are enough to come back with a model, an airflow figure and a drawing. OEM and ODM enquiries welcome.