How does an electrostatic precipitator work? Minute by minute

Physics explains the field. It does not explain why a cabinet that passed commissioning is emitting a plume six weeks later. Following a single puff of smoke through the machine does.

Short answer. In about a second of travel, the smoke is pulled into the hood, mixed with air, stripped of electrons at the ioniser, pushed sideways onto a plate, and left there as an oil film. The film drains; the air leaves.

Take a wok fired with oil at 200 °C. The plume that leaves it is a mix of vapour, fine droplets and partially burnt fat, at a temperature well above the room. It rises fast, entrains room air, and cools as it goes — which is the first chemical event, because cooling is what turns vapour into droplets that can be charged.

Second one: capture

The canopy has to be over the plume before it spreads past its edges. A wok line throws a plume about 0.6 m wide and 1.5 m high; a hood that sits 0.9 m above the range with a skirt catches it, one at 1.4 m with no skirt catches half. Everything downstream operates on the half it caught.

Inside the duct the air accelerates to around 8 m/s, which is the design velocity: fast enough to keep grease moving, slow enough not to add pressure loss for nothing.

Seconds two to four: charging

The airstream reaches the cabinet and slows to 2–3 m/s as it enters the wider section. It passes the pre-filter, then the ioniser. In the high-field region around the wire, ions attach to the droplets in microseconds. A droplet that misses the ioniser — because the velocity profile pushed it down one side — arrives at the plates uncharged and goes straight through.

This is the mechanism behind a fault that looks like a mystery: a cabinet with a clean cell and a plume usually has a blocked pre-filter, and the blockage has distorted the flow so much that part of the airstream never sees the ioniser.

Seconds four to five: collection

Between the plates the droplet drifts sideways at a few centimetres per second while the air moves a thousand times faster. It reaches a plate, sticks, and joins the film already running down it. The air that exits has lost 95–98% of its particle mass and reads 1–2 mg/m³ at the test point.

Minutes to weeks: what happens to the catch

The film runs to the sump and out of the drain. If the drain is blocked, the sump fills, the cell sits in grease, and the unit starts to arc. If the drain is clear but the wash interval is too long, the film thickens, the effective gap closes, and efficiency decays before anything trips.

That decay is the whole reason for a wash schedule tied to the cooking rather than to the calendar, and the reason a self-cleaning cabinet exists for sites where nobody will hold the schedule. Both are answers to the same problem, and both are on the kitchen ESP page with their wash intervals stated.

For a first-pass budget, the ESP purifier list gives the model, the airflow and the cabinet size side by side.