ESP filters 4,000–64,000 m³/h · CE certified · ISO 9001 · Shipping to 80+ countries

info@souniny.com / WhatsApp +86 189 2910 1713

Note · Food industry

Remove steam and odours in food production areas: two problems, not one

The words get used together so often that they are treated as one phenomenon. They are not: steam is water vapour, odour is gas-phase chemistry, and a device that removes grease aerosol removes neither.

Short answer. Steam is removed by extraction and condensation, not filtration. Odour is removed by carbon or scrubbing after the grease is gone. A precipitator removes neither, and running one on saturated air causes arcing and corrosion.

Steam: an extraction and condensation problem

Water vapour passes through every filter and every cell because it is a gas, not a particle. It becomes visible only when it condenses — which happens in the duct, on the roof, or in the neighbour's window.

The practical fixes are extraction rate, duct insulation (so the vapour stays vapour until it reaches the terminal), and where the load is heavy, a condensing hood or a cooling section ahead of any filter.

What steam does to the equipment behind it

Saturated air in a precipitator means condensation on insulators, leakage current, arcing and eventual corrosion. If a steam-heavy process has to be filtered, the moisture is taken out first — by cooling and mist elimination — or the cabinet is designed wet from the start.

Odour: after the grease, always

Carbon adsorbs gas-phase compounds and blinds instantly on grease aerosol. The sequence is: capture, grease removal, moisture removal where needed, then carbon. Skipping a stage does not save money; it moves the cost into media replacement.

Three process examples

  • Steam ovens and kettles: mostly moisture, little grease. Extract generously, insulate the duct, no cell needed.
  • Fryers and grills: mostly grease, little moisture. Cell first, carbon if odour is a condition.
  • Rendering and smokehouses: both, plus odour. Cooling and mist elimination, then cell, then carbon — or a wet scrubber if the load justifies it.

The test that settles it

Look at the plume on a cold morning. White and dissipating quickly is water. Blue-grey and persistent is aerosol. The first needs extraction; the second needs a cell. Getting that diagnosis wrong is the most expensive mistake in this area.

For the aerosol case the cabinet is the answer, sized from 4,000 to 64,000 m³/h, with the carbon stage behind it. The electrostatic precipitator pages give both, and the application notes explain which process each model suits.

Start from the electrostatic precipitator overview if you need the whole range in one view, then narrow to the model from the airflow.

Next step

Send the layout. We will confirm the model.

Appliance list, hood length and the duct route are enough to come back with a model, an airflow figure and a drawing. OEM and ODM enquiries welcome.

Size it in 30 seconds Chat on WhatsApp

Typical reply within one working day · MOQ 1 unit